Operating Instruction for Generator Manual Transfer Switch

1. Turn ALL circuit breakers off.
2. Start Generator per the manufacturer’s instructions.
3. Slide interlock and turn generator breaker on.
4. Turn circuit breakers on one at a time to avoid overloading the generator.
5. No more than 10 single pole 20-amp breakers should be on a time, possibly less.
6. Turning off individual appliances fed by breakers lowers the demand of the generator.

NOTE: Range, oven, furnace, and air conditioning CANNOT be run on generator power. Electric hot water heater can be operated if all other power use is at a minimum.

When Utility Power is Restored
1. Shut down generator per manufacturer’s instruction.
2. Turn off generator breaker.
3. Slide interlock.
4. Turn main breaker and all other branch breakers on.